AC HOME
Alternatively, you can complete the restart by switching off the circuit breaker or residual current circuit breaker and switching it on again after waiting at least 30 seconds.
AC BUSINESS
You can complete the restart by switching off the circuit breaker or residual current circuit breaker and switching it on again after waiting at least 30 seconds. The waiting time is required for the capacitors to discharge fully.
To correct an error, however, it is better to reset the charging controller. You must open the EV charging box to do so.
Risk to life due to electric shock
There is a risk of electric shock when working on the electrical installation of the EV charging box. All work which requires the EV charging box to be opened may be carried out only by an electrician.
Also observe the documentation for the EV charging box (assembly instructions and operating manual). You can download the documents in the product catalogue.
The Reset button is on the bottom right of the charging controller beside the LEDs under the DIP switch.
AC SMART
To restart an AC SMART EV charging box, turn off the circuit breaker or residual current circuit breaker and switch it back on after waiting at least 30 seconds.
The EV charging box will conduct a self test, and the LEDs will flash green during this time.